[email protected]
|
+91 9875070932
Home
Company
About Us
Vision & Mission
History
Infrastructure
Team
Products
Turbine Series
Gas Burners
Light Oil Burners
Heavy Oil Burners
Dual Fuel Burner (Gas - Light Oil)
Dual Fuel Burner (Gas - Heavy Oil)
Laminar Air Flow Burners
Gas Burners
Light Oil Burners
Heavy Oil Burners
Dual Fuel Burner (Gas - Light Oil)
Dual Fuel Burner (Gas - Heavy Oil)
High Temperature Burners
Gas Burners
Light Oil Burners
Heavy Oil Burners
Dual Fuel Burner (Gas - Light Oil)
Dual Fuel Burner (Gas - Heavy Oil)
New Generation Burners
Gas Burners
Light Oil Burners
Heavy Oil Burners
Dual Fuel Burner (Gas - Light Oil)
Dual Fuel Burner (Gas - Heavy Oil)
Customised Burners
Gas Burners
Light Oil Burners
Heavy Oil Burners
Dual Fuel Burner (Gas - Light Oil)
Dual Fuel Burner (Gas - Heavy Oil)
Burners System Equipment
Gas Pressure Reducing system
Light Oil Pumping Unit
Heavy Oil Heating and Pumping Unit
Gas Heaters
Infra-Red Heater
Blanket Heater
Khadi Heater
Forced draft Infra-Red Heater
Dryer Gas Fired for
Technology
Applications / Services
Clients
References & Certificate
Case Study
Inquiry
Contact Us
High Temperature Burners
/
Heavy Oil Burners
Heavy Oil Burners
Technical Specification:
Optimal fuel / air mixture.
Special grade combustion head.
Special design and low noise levels.
Single –Stage, Two-stage and Fully Modulating operation.
Flame control with Photocell.
Easy access to all equipment without disassembling the burner,
Control of the combustion air with the air pressure switch.
Easy installation and operation.
Accurate temperature controlling for Heating unit.
Split design Heating and Pumping unit.
NHS Series Heavy Oil Burner Fully Modulating Video Reference Link
:
https://youtu.be/dvanckWCyFI
BURNER
MODEL
HEAT OUTPUT
(KCal)
HEAT OUTPUT
(kW)
HEAVY OIL
CONSUMPTION(Kg/Hr)
OPH ELECTRICAL
HEATER(KW)
MOTOR
(HP)
VOLTAGE
(Ph)
OIL PUMP
MOTOR(KW)
FLAME LEGTH
(Mtr)
FLAME DIA
(Mtr)
BACK PRESSURE
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Graph
NHS 50
8,600
43,000
10
50
0.88
4.39
2.00
0.25
3
1.1
0.14
0.32
0.08
0.14
NHS 100
17,200
86,00
20
100
1.76
8.78
2.00
0.25
3
1.1
0.28
0.63
0.17
0.29
NHS 150
25,800
129,000
30
150
2.63
13.16
2.00
0.25
3
1.1
0.35
0.77
0.19
0.33
NHS 220
34,400
189,200
40
220
3.51
19.31
2.00
0.5
3
1.1
0.40
0.94
0.21
0.38
NHS 300
43,000
258,000
50
300
4.39
26.33
2.00
0.5
3
1.1
0.53
1.10
0.26
0.42
NHS 500
86,000
430,000
10
500
8.78
43.88
3.00
1
3
1.1
0.63
1.41
0.29
0.49
NHS 700
116,100
580,500
135
675
11.85
59.23
4.50
1
3
1.1
0.73
1.64
0.32
0.55
NHS 900
159,100
786,900
185
915
16.23
80.30
4.50
2
3
1.1
0.86
1.91
0.36
0.61
NHS 1400
236,500
1,161,000
275
1350
24.13
118.47
6.00
2
3
1.1
1.05
2.32
0.40
0.69
NHS 1800
313,900
1,591,000
365
1850
32.03
162.35
9.00
3
3
1.5
1.20
2.72
0.45
0.77
NHS 2700
473,000
2,365,000
550
2750
48.27
241.33
12.00
3
3
1.5
1.48
3.31
0.51
0.88
NHS 4250
774,000
3,655,000
900
4250
78.98
372.96
18.00
7.00
3
2.2
1.84
4.15
0.59
1.02
NHS 5500
1,032,000
4,730,000
1200
5500
105.31
482.65
24.00
10.00
3
2.2
2.10
4.69
0.65
1.10
NHS 6500
1,204,000
5,848,000
1400
122.86
596.73
24.00
12.00
549.44
3
2.2
2.28
5.25
0.68
1.19
NHS 7500
1,376,000
6,536,000
1600
7600
140.41
666.94
36.00
15.00
3
3.0
2.41
5.59
0.71
1.24
NHS 9500
1,462,000
8,170,000
1700
9500
149.81
833.67
36.00
20.00
3
3.0
2.53
6.29
0.73
1.35
Efficiency
Economy
Ecology
Quality
Performance
Reliable